Pressure transmitters with piezoresistive sensing principle, membrane stainless steel Typ: DPS
from 0-40 mbar to 0-16 bar
Accuracy class 0,3 FS
Service intended: Relative and absolute pressure measurement of low and medium pressure ranges, gaseous and liquid media, the flush diagram type also for highly viscous and crystallizing pressure media. According to directive 97/23/EG.
Fields of application:
● Plant and mechanical engineering
● ventilation and air-conditioning technology
Get offer
Downloads
Approvals
Explosionsschutz gemäß ATEX 2014/34/EU
Zündschutzart Ex II 2 GD c Tx BVS 12 ATEX H/B 079 DEKRA EXAM GmbH, benannte Stelle 0158
Konformitätserklärung
Druckgeräterichtlinie 2014/68/EU
Case
Stainless steel 304S
Protection class
IP 65 per EN 60529 / IEC 529
Pressure connection
Stainless steel 316 Ti
G1/2B per EN 837-1
G3/4B with flush diaphragm
G1/4 female
Sensing element
st. st. 316L, Measuring bridge: piezoresistive
Pressure and overpressure ranges
see Technical Details page 05.0202
Electrical connection
L-plug EN175301-803 Form A
Signal output 1) Power supply
4 ... 20 mA, 2-wire Ub = 7,5 ... 30 V DC
Load: Rb [ Ohm ] : ( Ub [ V ]-7,5 [ V ] )/0,025 [ A ]
0 ... 10 V, 3-wire Ub = 12 ... 30 V DC
Load: >10 kOhm
Power consumption
P max = 0,75 W
EMC-Directive
2004/108/EC EN 61326 Emission (Group 1, Class B. Immunity, industrial locations)
Permissible temperatures Tmin / Tmax
Storage temperature - 40 ... +100 °C
Medium temperature - 25 ... + 80 °C
Ambient temperature - 20 ... + 70 °C
Accuracy
Linearity + hysteresis + repeatability
<0,3%FS, < 0,2%BFSL
Temperature error
Mean TK of zero < 0,2 % FS / 10 K
Mean TK of range < 0,2 % FS / 10 K
Optional extras
1) see digital indicator