Pressure transmitters with thick film strain gauge, ceramic Typ: NCS
from 0-1 bar to 0-400 bar
Accuracy class 1,0 FS
Service intended: Relative and absolute pressure measurement of gaseous and liquid media, the flush diagram type also for highly viscous and crystallizing pressure media.
According to directive 97/23/EG.
Fields of application:
● Plant and mechanical engineering
● ventilation and air-conditioning technology
● Pneumatics, hydraulics
Get offer
Downloads
Approvals
Explosionsschutz gemäß ATEX 2014/34/EU
Zündschutzart Ex II 2 GD c Tx BVS 12 ATEX H/B 079 DEKRA EXAM GmbH, benannte Stelle 0158
Konformitätserklärung
Druckgeräterichtlinie 2014/68/EU
Case
Stainless steel 304S
Degree of protection
IP 65 per EN 60529 / IEC 529
Pressure connection
Stainless steel 316Ti
G1/2B per EN 837-1
G3/4B with flush diaphragm
G1/4 female
Sensing element
Ceramic diaphragm,
Measurig bridge, thick film strain gauge
Pressure and overpressure ranges
see Technical Details page 05.0312
Electrical connection
L-plug EN175301-803 Form A
Signal output1) Power supply
4 ... 20 mA, 2-wire Ub = 7,5 ... 30 V DC
Load: Rb [ Ohm ] : ( Ub [ V ]-7,5 [ V ] )/0,025 [ A ]
0 ... 10 V, 3-wire Ub = 12 ... 30 V DC
Load: >10 kOhm
Ratiometric 0,5 ... 5,5 V
Load: >4,5 kOhm
Power consumption
P max = 0,75 W
EMC-Directive
2004/108/EC EN 61326 Emission (Group 1, Class B. Immunity, industrial locations)
Permissible temperatures Tmin / Tmax
Storage temperature - 40 ... +100 °C
Medium temperature - 25 ... + 80 °C
Ambient temperature - 20 ... + 70 °C
Accuracy
Linearity + hysteresis + repeatability
<0,5% BFSL / 1% FS, see page 05.0402
Temperature error
Mean TK of zero < 0,2 % FS / 10 K
Mean TK of range < 0,2 % FS / 10 K
Optional extras
1) see digital indicator